Description
YSD-220 Fully-auto Biochemistry Analyzer


Features
  • Random access, discrete automatic biochemistry analyzer, insert emergency at any time
  • High performance and reasonable price, It is the best economical choice from semi-auto upgraded to fully-auto analyzer
  • Probe performance: Liquid level detection, all-round anti-collision protection and inventory checking, have automatic stop and alarm prompt for an obstacle
  • Probe cleaning: Automatic washing for both interior and exterio


Analysis System
 
  • Test Speed: constant 160tests/hour, up to 220tests/hour
  • Test method: End-point, Fixed-time (two point method), kinetic
  • Reaction tray:  81 UV cuvettes (disposable)
  • Mini reaction volume: 150μl, save reagent cost
  • Insert emergency at any time
  • Support linear and non-linear calibration
  • Heating method: solid constant temperature closed direct heating
  • Temperature equilibrium time: less than 3minutes,
  • Reaction Temperature: 37±0.2°C
  • Temperature Fluctuation: ± 0.2°C
 
Optical System

 
  • Integrated full closed optical system, after spectrometric method, no mechanical parts, not moldy, no maintenance cost
  • 8 wavelengths, selectable among 340-800nm
  • Absorption range: 0.00-4.00Abs
  • Halogen-tungsten lamp has more than 2000hrs service time
  • Center wavelength deviation: ±2nm, half wave width less than 12nm
  • Stray light less than 0.3%
  • Resolution: 0.0001Abs
 
Reagent/Sample Tray

 
  • 60 reagent + 30 sample positions
  • Advanced reagent tray refrigeration system, temperature: 4-12°C (optional function)
  • Automatically detect reagent remain, real time display reagent remain
  • Reagent bottles with 15ml,30ml,50ml,70ml are available.
  • Support single/ dual reagents, reagents are open
  • Real time display reagent tray status
  • Automatically judge substrate depletion
 
Sample adding and rinsing system


 
  • Sample volume:             2-100μl , 0.1μl by step,
  • Reagent volume:                   20-500μl, 1μl by step
  • Water consumption:    less than 3L/hour
 
 
Operation System
  • Windows XP or Windows 7 Home, easy to operate
  • Automatic storage, automatic backup, no time limit and storage limit,
  • Permanently preserve all kinds of data
  • English print repo rt, the user can modify the print format
  • English online help and operation guide
  • The test parameter setting is completely open
  • Real-time monitor the status of sample tray, reagent tray and reaction tray
  • Real-time monitor the status of reaction cup, lamp and purified water
  • Real-time display the reaction tray humidity and reagent remain
  • Real-time display the reaction curve, calibration curve and QC chart
  • Automatically check calibration curve and select the calibration type with the best fitting
  • Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
  • Inspection and Judgment: Reaction end point judgment, reaction linear range judgment, substrate depletion judgment, reaction limit inspection, reagent blank absorbance judgment
  • RS232 standard interface, support the intranet and remote printing
 

Technical Specifications               
                                     
Performance
Type: Discrete Automatic, Random Access
Principle:   Absorption Spectrometry, Turbidimetry
Throughput: Constant 160tests/hour (without ISE)
Test method: End-point, Fixed-time, Kinetic
                    Support dual reagents/double wavelength
Test sequence: Run tests in strict accordance with sample sequence,
                       Insert emergency at any time

Optical System

Light Source:  Halogen-tungsten lamp, 12V/20W
                      More than 2000hrs service time
Spectrometric Method:  After spectrometric method
Wavelength: 8 wavelengths, selectable among 340-800nm
Absorption Range:  0-4.0Abs
Optical System: Integrated full closed optical system
 

Reaction system

Reaction Tray:  81 positions for cuvettes
Reaction Volume: Mini 150μl
 

Sample system

Sample Tray:  30 positions
Sample Volume: 2-100μl, 0.1μl by step
Online Sample: 30 samples/ batch, unlimited batch input
 

Reagent System

Reagent Tray:  60 positions, open system
Reagent Volume:  20-500μl, 1μl by step
Reagent Bottle: Bottles with 15ml,20ml,30ml,50ml,70ml are available dead volume<1ml
 

Temperature Control System

Heating Mode: Solid constant temperature closed direct heating
Equilibrium Time: less than 3minutes
Reaction Temperature:  37±0.2°C
Temperature Fluctuation: ± 0.2°C
Refrigeration system: For option
 

Calibration and QC

Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
                            Automatically check calibration curve and select the calibration type with the best fitting
QC Type: Real time QC, QC in one day, QC between days;
QC Rules: QC chart: L-J, Cumulative, Twin Plot, Multi-rule; default: Westguard
Status Monitoring:  Real -time monitor the sample tray, reagent tray, reaction tray, reaction cup, lamp, purified water; Real-time display reaction tray humidity, reagent remain, reaction curve, calibration curve and QC chart.
Inspection & Judgment:  Reaction end point judgment, reaction linear range judgment, substrate depletion judgment, front belt detection,reaction limit inspection, reagent blank absorbance judgment
 

Operation and Print

Operation System: Windows XP or Windows 7 Home
Database: SQL Server
Data Storage: Automatic storage and backup, permanently preserve all kinds of data
Print Content: Print content can be customized
Print Format: Provide a variety of print format
 

Working Conditions

Water Consumption: less than 3L/hour
Power Supply: AC 220 ±22V  50HZ ±1HZ
Power: Max 200VA
Ambient Temperature: 10°C-30°C
Dimension(L*W*H): 78*58*55cm
Net Weight:  45K